PolymersCA-41 FDA

High flow resin suitable for applications requiring FDA compliance.

  • UL-94 HB
  • FDA Compliant
  • General Purpose
  • Injection Molding
  • Food Grade

Optical

TEST METHOD

UNITS

CA-41 FDA

Yellowness Index

ASTM D1925

-

< 1.0

Refractive Index

ASTM D542

-

1.49

Luminous Transmittance

ASTM D1003

%

92

Haze

ASTM D1003

%

< 1.0

Mechanical

TEST METHOD

UNITS

CA-41 FDA

Tensile Strength

ASTM D638

psi

7800

Modulus of Elasticity

ASTM D638

psi

408000

Impact Strength – Izod (Notched)

ASTM D256

ft-lb/in

0.3

Rockwell Hardness

ASTM D785

M scale

74

Elongation

ASTM D638

%

2.4

Flexural Strength

ASTM D790

psi

11700

Impact Strength – Falling Weight (1/8”)

ASTM D5420 GB

in-lb

2

Thermal

TEST METHOD

UNITS

CA-41 FDA

Molding Shrinkage

ASTM D955

%

0.2-0.6

Melt Flow Rate

ASTM D1238

g/10 min

26

Vicat Softening Temperature

ASTM D1525

°F

194

Heat Deflection Temperature Under Load (264 psi)

ASTM D648

°F

163

Coefficient of Linear Thermal Expansion (-30 to 30°C)

ASTM D696

mm/(mm-oC)

6 X 10^-5

Other

TEST METHOD

UNITS

CA-41 FDA

Specific Gravity

ASTM D792

-

1.19

Relative Thermal Index

UL 746 ABC

°C

50

Flammability

UL 94

-

HB

Download

**Applicable to the acrylic substrate

These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use are beyond our control. We recommend that the prospective user determine the suitability of our materials and suggestions before adopting them on a commercial scale.