PolymersCP-1000 IG

Excellent environmental stability and transparency. Ideally designed for injection molding of Medical devices and housewares products in contact with food use. Excellent recovery time and weatherability.

2.7
Melt Flow Index
  • FDA Compliant
  • USP Class VI
  • Medical/Biocompatible Grade

Mechanical

TEST METHOD

UNITS

CP-1000 IG

Tensile Strength

ASTM D638

psi

6100

Elongation

ASTM D638

%

37

Modulus of Elasticity

ASTM D638

psi

270000

Flexural Strength

ASTM D790

psi

8900

Impact Strength – Izod (Notched)

ASTM D256

ft-lb/in

1.2

Impact Strength – Falling Weight (1/8”)

ASTM D5420 GB

in-lb

56

Optical

TEST METHOD

UNITS

CP-1000 IG

Luminous Transmittance

ASTM D1003

%

91

Haze

ASTM D1003

%

< 3

Refractive Index

ASTM D542

-

1.49

Yellowness Index

ASTM D1925

-

< 1.0

Thermal

TEST METHOD

UNITS

CP-1000 IG

Vicat Softening Temperature

ASTM D1525

°F

211

Heat Deflection Temperature Under Load (264 psi)

ASTM D648

°F

176

Melt Flow Rate

ASTM D1238

g/10 min

2.7

Coefficient of Linear Thermal Expansion (-30 to 30°C)

ASTM D696

mm/(mm-oC)

12 X 10^-5

Molding Shrinkage

ASTM D955

%

0.2-0.6

Other

TEST METHOD

UNITS

CP-1000 IG

Specific Gravity

ASTM D792

-

1.16

Download

**Applicable to the acrylic substrate

These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods of use are beyond our control. We recommend that the prospective user determine the suitability of our materials and suggestions before adopting them on a commercial scale.